    摘要:

    为得到合理的注浆参数,控制地表沉降,降低盾构同步注浆参数不合理造成的地表沉降过大风险,该文依托某磁浮T2站—磁浮T3站区间盾构隧道工程,采用数值模拟方法,研究注浆压力、注浆量和浆液弹性模量对地表变形的影响规律。结果表明:隧道同步注浆对地表沉降控制影响显著,注浆压力、等代层厚度和浆液弹性模量越大,地表沉降则越小;随着3个参数的增加,地表沉降变化幅度越小,逐渐趋于稳定,注浆效果趋于饱和;综合考虑注浆有效性与经济性,建议采用200~250 kPa注浆压力、5.4 m3/环注浆量及200~250 MPa浆液弹性模量。现场应用效果验证了该参数组合的合理性。研究成果为类似盾构隧道工程注浆加固提供了参考。

    Abstract:

    In order to determine reasonable grouting parameters, control surface settlement, and reduce the risk of excessive surface settlement caused by irrational synchronous grouting parameters, this study studied the shield tunnel project between maglev T2 station and maglev T3 station. A numerical simulation method was adopted to study the influence of grouting pressure, grouting volume, and the elastic modulus of slurry on surface deformation. The results show that the tunnel synchronous grouting has a significant effect on surface settlement control. A greater grouting pressure, equivalent grouting layer thickness, and elastic modulus of slurry mean a smaller surface settlement. As the three parameters increase, the variation range of surface settlement decreases and gradually stabilizes, indicating that the grouting effect tends to saturate. By considering both grouting effectiveness and economic efficiency, it is recommended to adopt a grouting pressure of 200?250 kPa, a grouting volume of 5.4 m3 per ring, and an elastic modulus of slurry between 200 and 250 MPa. The on-site application has verified the rationality of this parameter combination. The research provides a reference for grouting reinforcement in similar shield tunnel projects.

    参考文献
    相似文献
    引证文献
引用本文

罗旭,张召峰,傅鹤林,等.盾构同步注浆参数对地表变形影响研究[J].中外公路,2025,45(3):172-182.
LUO Xu, ZHANG Shaofeng, FU Helin, et al. Research on Influence of Shield Synchronous Grouting Parameters on Surface Deformation[J]. Journal of China & Foreign Highway,2025,45(3):172-182.

复制
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2024-03-18
  • 最后修改日期:2024-08-20
  • 录用日期:
  • 在线发布日期: 2025-06-23
  • 出版日期:
文章二维码
网站二维码
期刊公众号